Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs

Journal
Watrous GK, Moens NM. Can Vet J. 2017 Apr; 58 (4): 377-382.

This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. T

hirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function.

The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.